10 kVA / 10000 Watt Power Conditioner & Battery Backup ...

02 Dec.,2024

 

10 kVA / Watt Power Conditioner & Battery Backup ...

This unit is fantastic and versatile. It has a built in isolation transformer which allows you to select/wire pretty much any output voltage configuration you want. The input is 2 hots (L12 and N1) and 1 ground (G1). The N1 name is misleading, it is really for the second hot. If you were in another country where 230 VAC is the default, I guess it would neutral, but in the US, its HOT 2. The output terminal allows for a variety of configurations, but I always use 120/240VAC split phase. To get that, you put the included jumper on N11 and L22. Then output HOT 1 is N22, output NEUTRAL is either N11 or L22 (jumper), output HOT 2 is L11, and output GROUND is G2.

For more information, please visit our website.

UPS 10kVA Online Uninterruptible Power Supply With 1 ...

Highlight:

ups 10kva online

,

rack mount online UPS 10kva

,

10KVA Online Uninterruptible Power Supply

UPS 10kVA Online Uninterruptible Power Supply With 1 Hour Backup

Online UPS 10kVA with 1 hour backup
 
High frequency online 1 kVA ~ 40 kVA Tower UPS
(1 phase input 1 single phase output, 3phase input 1 phase output, 3 phase input 3 phase output)


CNE series All intelligent high frenquency pure online UPS, which are generally used on places required high quality electricity,such as hospital equipments,corporations,IT loading equipments,industrial computer terminals.As UPS inverter circuit always in a state of work,the stored energy of UPS can be inverted and output alternating current without switching.CNE series UPS support different types of operation systems,apply to TCP/IP local LAN and support the networking monitoring of UPS.
 

You will get efficient and thoughtful service from Chengyue.

Product Features

 
&#;Support LBS synchronic control
&#;Intelligent Fan speed regulation function
&#;Support bypass maintenance(three phase input single phase output)
&#;LCD display function,user friendly display interface
&#;Three-stage extensible charging design to ensure a more remarkable perfomnce of the batteries.
&#;Support parallel opretion of more than 3 machines with shared battery packs.
&#;Support DC cold starting;without utility, the load can keep operating with the power offered by batteries.
&#;Powerful charging function is convinient to extense the capacity of standby batteries.Intelligent charging mode even extending battery life to cut down expenditures.
&#;Support automatic restart function: when utility goes normal after UPS is shutdown under battery mode,UPS can automatic restart.
&#;Good technical indicators: the approximate 1 input power factor,largely decreased the pollution to utility grid and improved the use ratio of grid,so CNE series UPS are real eco-type power.
&#;Support fungas proofing, moisture proofing and salt spray fog proofing, in order to decrease or eliminate the adverse impacts of complexing environment to electron devices;Dustproofing function and strong envirnmental adaptability.
 
Function Features
&#;Advanced DSP digital control technology, guarantee high UPS performance,products stable and quality reliable.
&#;Zero switching time:when the city electricity is abornomal,UPS will turn to battery mode with zero time,which can effectively ensure the safety and reliability of the instruments.
&#;Green &Environment:Meet the State Administration of electronic information products&#; pollution control,will cause no harm to human and envirnment under normal usage.
&#;Frequency adaptive system: In order to meet different power system requirements, it can be set to fixed or automatic idetification to fit for 50Hz/60Hz.
&#;Input power factor correction function enable the factor to be over 0.99 to avoid grid environment pollution,so as to save energy and decrease cost.
&#;Wide input voltage and frequency range:Even in places where electricity environment is very bad, it can also keep stable work under utility supply mode,which decrease the number of battery discharge and prolong the service life of batteries.
&#;Powerful smart slot provide rich extending functions,can choose SNMP network monitoring card to realise remote supervision,management and maintenance.
 
 
Data Sheet
 

ModelCNE-CNE-LCNE-CNE-LCNE-CNE-LCNE-CNE-CNE-LCNE-LRated capacity1KVA/0.8KW2KVA/1.6KW3KVA/2.4KW6-10KVA/4.8-8KWInputVoltage range90-285VAC120-274VACFrequency40-60HZ(adjustable) Power factor0.99OutputVoltage range220VAC(1±2%)20VAC(1±1%)Frequencysame as city electricity; (50±0.2)HZ in battery modesame as city electricity; (50±0.1)HZ in battery modePower factor0.8Overload capability125% overload, 1 minBatteryTypeMaintenance free batteryVoltgage3 of 12v/7Ah36VDC no battery6 of 12v/7Ah72VDC no battery8 of 12v/7Ah96VDC no battery16 of 12v/7Ah16 of 12v/9Ah192VDC no batterySize(W*D*H mm)144*350**425**425**560**533*501Net weightKG125.722..Communication(Standard)RS232 communication interface

 

If you are looking for more details, kindly visit HAIWU HHU series Tower type 1-10kva Online UPS Power Supply.

ModelCNE-LCNE-LCNE-LCapacity10KVA/8KW20KVA/16KW30KVA/24KWInputconnection Three phase+ ground wirerated voltage 208/220VACVoltage range=-20%Frequency range40-70hzPower factor&#;0.99Outputoutput voltage 208/220VACVoltage accuracy1%Frequency accuracy50/60HZ±0.01HZWaveform distortionLinear load &#;2% Nonlinear load&#;3%Overload capability100%, and then switch to bypass after 1hr; 125%, and then switch to bypass after 10mins; 150%, and then switch to bypass after 1mins;Peak factor>3:1Switch time0ms(city electricity mode &#;battery mode)Batterycell16 (16-20 adjustable)20 (18-20 adjustable)Charging current1A/2A/4A/6A/12A adjustableDisplayLCD/LED Displays input and output voltage,frequency,battery voltage and capacity, load percentageControl
managementPage intelligent RS232/USB, SNMP card(optional)Working environmentTemperature 0&#; to 40&#;Humidity 0 to 95% without condensationNoise(within 1m) &#;58dB@1m&#;60dB@1mPhisical propertyWeightNetSize(W*D*H)190*442**575**815*826