ADVANTAGES OF AIR-TO-WATER HEAT PUMPS

04 Nov.,2024

 

ADVANTAGES OF AIR-TO-WATER HEAT PUMPS

Both geothermal water-to-water heat pumps and air-to-water heat pumps should be evaluated based on "net COP" rather than the COP of the heat pump as a standalone device. Net COP is calculated by dividing the rate of heat output by the total electrical power required to run the heat pump and its associated circulators. Net COP is a better indicator of the true operating cost of either type of hydronic heat pump since the power required by the required circulators is factored in. 

Check now

For a geothermal water-to-water heat pump, this would include the circulator(s) used to create flow in the earth loop and the circulator that provides flow through the load side of the heat pump. Some earth loops require multiple circulators connected in series to provide sufficient head and flow. The total power required by these circulators can be several hundred watts. Both the geothermal water-to-water heat pump and an air-to-water heat pump require a load side circulator. 

To see the effect of net COP, consider a geothermal water to water heat pump with a heating capacity of 48,000 Btu/hr. The heat pump compressor draws 4.2 KW when operating. Its earth loop requires two circulators, piped in series, operating at 220 watts each. The load side circulator draws 180 watts. Calculate the COP of the heat pump itself, and the net COP of the heat pump with its associated circulators.

The COP of the heat pump as a standalone device is:

$$COP_{HPonly}={ {48,000 Btu / hr\over [] watt · 3.413 {Btu / hr\over watt}}}= 3.35$$

The net COP of the heat pump and its associated circulators is:

$$COP_{net}={ {48,000 Btu / hr\over [(2 · 220) + + 180] watt · 3.413 {Btu / hr\over watt}}}= 2.92$$

In this example, the net COP is about 13% lower than the COP of the heat pump as a standalone device.

Assume that an air-to-water heat pump has an output of 48,000 Btu/hr, with a corresponding electrical input of 5.5 KW. The load side circulator requires 180 watts. Calculate the COP of this heat pump alone and the net COP of the heat pump and its load side circulator.

The COP of the air-to-water heat pump alone is:

$$COP_{HPonly}={ {48,000\, Btu / hr\over []\,watt · 3.413 {Btu / hr\over watt}}}= 2.56$$

The net COP of the heat pump and its load side circulator is:

$$COP_{net}={ {48,000\, Btu / hr\over [ + 180]\,watt · 3.413 {Btu / hr\over watt}}}= 2.48$$

In this example, the net COP is only about 3% lower than the COP of the air-to-water heat pump as a standalone device. Even though the air-to-water heat pump draws an additional 1.3 kilowatts of electrical power compared to the geothermal heat pump, its net COP, in this example, is only about 12% lower than that of the geothermal heat pump. It&#;s also important to remember that the COP of any heat pump is highly dependent on its operating conditions, and thus, there are scenarios where the net COP of an air-to-water heat pump could exceed the net COP of a geothermal water- to-water heat pump.

 

 

Air to water heat pump: Monoblock or Split - Wotech

What are the differences between monoblock and split air to water heat pumps?

What is Monoblock heat pump?


The air-to-water heat pump for home heating and domestic hot water, Monoblock type , consists of an outdoor unit and a control panel. ln contrast to split devices, in monoblock heat pumps the entire refrigeration system is located in one unit mounted outside the building. All connections containing refrigerant gas are made and filled with refrigerant gas at the production stage of the pumps. The gas is hermetically sealed in the outdoor unit, and the tightness of the system is carefully checked by the manufacturer, During the assembly of monoblocks, only pipes filled with water or glycol are led out of the outdoor unit.

Link to Forlssman


Advantages of monoblock heat pump:


Refrigerant circuit completely contained in monoblock

No refrigeration certificate required for installation and maintenance

Suitable for both indoor and outdoor installation

Lower installation costs


What is Split heat pump?


The Split type air-to-water heat pump consists of two units - external and internal. The outdoor unit is connected to the indoor unit by refrigerant lines. The heat received in the evaporator raises the temperature of the refrigerant, which is directed to the compressor. The refrigerant with increased temperature and pressure gives off heat in the condenser and returns to the evaporator through the electronic expansion valve. The heating water receives heat from the condenser The circulation pump directs the heating water through the 3-way separating valve to the building's heating system or to the utility water heater coil.


Advantages of Split heat pump:


Can be installed further away from the property

No glycol / anti-freeze required


Which is right for your project?


Typically, most homes will require a monoblock system. Split systems are an option for more complex installations,is designed for cold climate( &#;-15C), if the days of winter is long and cold like Scandinavian countries.

Whenever making a decision as big as this, we highly recommend getting advice from a local heating expert.


Wotech offer both split and monobloc heat pumps to cater for individual homeowner requirements.Contact us to get the reliable heating solutions.


Are you interested in learning more about Split Air To Water Heat Pump? Contact us today to secure an expert consultation!